Radio Zürisee loft

Switzerland’s first radio loft was built in Rapperswil on Lake Zurich. Single as well as multi-split units and an evaporator control unit provide air conditioning for the loft and the studio, as well as the office and server rooms.
7RM0802_2000x1333

Radio Zürisee is based in the centre of Rapperswil, in the canton of St. Gallen. Since November 2019, however, the former Hotel Post has not just been broadcasting programmes. A 120-square metre loft space was built right next to the studio. It is used for seminars, meetings, concerts, wedding receptions or Christmas dinners for up to 100 people. CTA split air-conditioning units provide air conditioning for the premises. The company HS Kälte Wärme Klima GmbH, based in Siebnen, handled the entire heating/air conditioning design and installation of the split air-conditioning units.

Editorial, marketing and loft offices

  • 1x multi-split exterior unit, Fujitsu AOYG 30LAT4, 8 kW (courtyard)

  • 1x wall-mounted interior unit, Fujitsu ASYG 18LFCA (Editing office, 1st floor)

  • 1x wall-mounted interior unit, Fujitsu ASYG 07LMCE (Office vestibule, 1st floor)
     

  • 1x multi-split exterior unit, Fujitsu AOYG 30LAT4, 8 kW (courtyard)

  • 1x wall-mounted interior unit, Fujitsu ASYG 18LFCA (Media service office, 2nd floor)

  • 1x wall-mounted interior unit, Fujitsu ASYG 09LMCE (Marketing office, 2nd floor)

Studio 1 & 2, cooling for ventilation room

  • 1x split exterior unit, Fujitsu AOYG 14LVLA, 4.2 kW (courtyard)

  • 1x chest interior unit, Fujitsu AGYG 14LVCA (Studio 1)

  • 1x multi-split exterior unit, Fujitsu AOYG 14LVLA, 4.2 kW (courtyard)

  • 1x chest interior unit, Fujitsu AGYG 14LVCA (Studio 2)

  • 1x multi-split exterior unit, Fujitsu AOYG 45LATT, 12.5 kW (intermediate awning)

  • 1x evaporator control unit, ventilation control paned (to the ventilation room)

Server room (redundant)

  • 1x split exterior unit, Fujitsu AOYG 45LATT, 12.5 kW (intermediate awning)

  • 1x ceiling extension interior unit, Fujitsu ABYG 45LRTA (server room, ground floor)

  • 1x split exterior unit, Fujitsu AOYG 45LATT, 12.5 kW (intermediate awning)

  • 1x ceiling extension interior unit, Fujitsu ABYG 45LRTA (server room, ground floor)

A7A1147_1500x1000
One of the interior units
7RM1018_2000x1333

Server room cooling

7RM0882_1500x1000

The evaporator control for the ventilation of the hall

7RM1107_2000x1333

The air-conditioned radio studio with a view of the loft

7RM1155_1500x1000

Air-conditioned office spaces in the refurbished old building

Companies involved in the project

  • Building owner: Radio Zürisee, Rapperswil

  • Heating/air conditioning design and installation: HS Kälte Wärme Klima GmbH, Siebnen

  • Architecture and site management: Susanne Fritz Architekten

  • Split air-conditioning unit supplier: CTA AG, Münsingen BE

Company

Locations / ContactAbout UsMedia & DownloadsCareer

Contact

CTA Ltd.

Hunzigenstrasse 2

CH-3110 Münsingen

Tel. +41 31 720 10 00info@cta.ch

Copyright © 2022 CTA Ltd.

General Terms and Conditions of BusinessGeneral Terms of PurchaseData ProtectionCookie Consent